Chapin Hall 

1313 East 60th Street, Chicago IL, 60637 Find on Google Maps (opens in a new tab)

Chicago Building ID: 252061

Attribution: © Google 2025

Building Info

Square Footage
65,745 sqft
Lower than 83% of all buildings
0.5x median
124,364 sqft
1/2 median College/University
135,042 sqft
Built
1938
Primary Property Type
College/University
Community Area
Woodlawn
Ward
5
Owner
University of Chicago
View All Tagged UChicago Buildings

Note: Owner manually tagged. Logo used under fair use.

Emissions & Energy Information for 2023

Greenhouse Gas Intensity F
13.8 kg CO2e / sqft
#9 Highest of College/Universities 🚨
Higher than 95% of all buildings
2.2x median
6.2 kg CO2e / sqft
1.7x median College/University
8.3 kg CO2e / sqft
Total Greenhouse Gas Emissions
907.7 tons CO2e
Higher than 53% of all buildings
1.1x median
841.4 tons CO2e
0.8x median College/University
1,104.4 tons CO2e

Years Reported 9/9
A Help icon

  • 2015 data reported

    2015

  • 2016 data reported

    2016

  • 2017 data reported

    2017

  • 2018 data reported

    2018

  • 2019 data reported

    2019

  • 2020 data reported

    2020

  • 2021 data reported

    2021

  • 2022 data reported

    2022

  • 2023 data reported

    2023

Energy Breakdown for Chapin Hall

Fossil Gas Use (aka Natural Gas)
Not Reported

This data was not reported for this building this year, which likely means a value of zero for this field.

This Building Uses District Heating ❗

Although this building didn't burn any fossil gas on site, it's connected to a district heating system, a centralized system for heating multiple buildings. District heating systems can be fully electric, but in Chicago most district heating systems are fossil gas powered, meaning this building was most likely still heated with fossil gas.

Electricity Use
2,625,834 kBtu
Est. Electric Bill: $110,000 for 2023**
Lower than 61% of all buildings
0.7x median
3,580,332.6 kBtu
1/2 median College/University
5,566,941.2 kBtu
District Steam Use
8,136,656 kBtu
1.3x median
6,360,617.1 kBtu

Energy Mix C

Total Energy Use: 10,762,491 kBTU

Help icon
View Extra Technical & Historic Info
Source Energy Usage Intensity
Not Reported

This data was not reported for this building this year, which likely means a value of zero for this field.

Site Energy Usage Intensity
Not Reported

This data was not reported for this building this year, which likely means a value of zero for this field.

Full Historical Data Table for Chapin Hall

Year Overall
Grade
Emissions
Intensity
Sub-Grade
Energy Mix
Sub-Grade
Reporting Mix
Sub-Grade
GHG Intensity kg CO2e / sqft GHG Emissions metric tons CO2eEnergy Mix Electricity Use kBTU District
Steam Use kBTU
Source EUI kBTU / sqft Floor Area sqft Chicago Energy
Rating
2015 D F D A 16.21,065
29%Electricity
0%Fossil Gas
71%Other
2,955,483 7,097,828 271 65,745 -
2016 D F D A 16.21,066
30%Electricity
0%Fossil Gas
70%Other
3,144,644 7,328,832 284.3 65,745 -
2017 D F D A 15.61,025
29%Electricity
0%Fossil Gas
71%Other
2,941,710 7,246,338 273.1 65,745 -
2018 D F C A 161,055
27%Electricity
0%Fossil Gas
73%Other
3,055,879 8,234,182 280.8 65,745 1.0
2019 D F C A 171,119
24%Electricity
0%Fossil Gas
76%Other
3,022,544 9,751,398 307.2 65,745 1.0
2020 D F C A 14.3942.5
25%Electricity
0%Fossil Gas
75%Other
2,663,701 7,933,975 258.6 65,745 2.0
2021 D F C A 13.4879.9
26%Electricity
0%Fossil Gas
74%Other
2,633,863 7,586,056 251 65,745 2.0
2022 D F C A 14.5951.3
22%Electricity
0%Fossil Gas
78%Other
2,614,814 9,140,142 278.6 65,745 1.0
2023 D F C A 13.8907.7
24%Electricity
0%Fossil Gas
76%Other
2,625,834 8,136,656 260.7 65,745 1.0

* Note on Rankings: Rankings and medians are among included buildings, which are those who reported under the Chicago Energy Benchmarking Ordinance for the year 2023, which only applies to buildings over 50,000 square feet.

** Note on Bill Estimates: Estimates for gas and electric bills are based on average electric and gas retail prices for Chicago in 2021 and are rounded. We expect large buildings would negotiate lower rates with utilities, but these estimates serve as an upper bound of cost and help understand the volume of energy a building is used by comparing it to your own energy bills! See our Chicago Gas & Electric Costs Source (opens in a new tab) for the original statistics.

Data Source: Chicago Energy Benchmarking Data (opens in a new tab)

What Should We Do About This?

Own this Building? Take Action.