Building Info

Square Footage
127,535 sqft
Higher than 51% of all buildings
1.0x median
124,364 sqft
1.0x median Ice/Curling Rink
127,535 sqft
Built
2017
Primary Property Type
Ice/Curling Rink
Community Area
Near West Side
Ward
27
Owner
Not Tagged

Warning - Data Discrepancies Detected

We detected some issues with this building's data, so these grades may not be reflective of the building's true performance.

Emissions & Energy Information for 2023

Greenhouse Gas Intensity F
20182023152414.923.5
23.5 kg CO2e / sqft
#39 Highest in Chicago* 🚩
3.8x median
6.2 kg CO2e / sqft
1.0x median Ice/Curling Rink
23.5 kg CO2e / sqft
Total Greenhouse Gas Emissions
201820231,8992,9971,8992,997
2,997 tons CO2e
Higher than 87% of all buildings
3.6x median
841.4 tons CO2e
1.0x median Ice/Curling Rink
2,997.9 tons CO2e

Years Reported 5/6
A Help icon

  • 2018 data reported

    2018

  • 2019 data not reported

    2019

  • 2020 data reported

    2020

  • 2021 data reported

    2021

  • 2022 data reported

    2022

  • 2023 data reported

    2023

Energy Breakdown for Fifth Third Arena

Fossil Gas Use (aka Natural Gas)
201820231,335,61317,293,5841,335,61317,293,584
15,958,786 kBtu
Est. Gas Bill: $190,000 for 2023**
Higher than 85% of all buildings
2.9x median
5,517,828 kBtu
1.0x median Ice/Curling Rink
15,958,786.6 kBtu
Electricity Use
2018202311,717,17415,733,72511,717,17415,733,725
15,368,043 kBtu
Est. Electric Bill: $644,000 for 2023**
Higher than 88% of all buildings
4.3x median
3,580,332.6 kBtu
1.0x median Ice/Curling Rink
15,368,043 kBtu

Energy Mix B

Total Energy Use: 31,326,830 kBTU

49%Electricity51%Fossil Gas
Help icon
View Extra Technical & Historic Info
Source Energy Usage Intensity
20182023268488268.2487.8
Not Reported

This data was not reported for this building this year, which likely means a value of zero for this field.

Site Energy Usage Intensity
Not Reported

This data was not reported for this building this year, which likely means a value of zero for this field.

Full Historical Data Table for Fifth Third Arena

Year Overall
Grade
Emissions
Intensity
Sub-Grade
Energy Mix
Sub-Grade
Reporting Mix
Sub-Grade
GHG Intensity kg CO2e / sqft GHG Emissions metric tons CO2eEnergy Mix Electricity Use kBTU Fossil Gas Use kBTUSource EUI kBTU / sqft Floor Area sqft Chicago Energy
Rating
2018 C F A A 17.92,285
90%Electricity
10%Fossil Gas
0%Other
13,288,887 1,407,292 303.3 127,535 1.0
2019- 14,412,660 1,683,798 127,535 -
2020 C F A A 14.91,899
90%Electricity
10%Fossil Gas
0%Other
11,717,174 1,335,613 268.2 178,172 2.0
2021 C F B A 23.32,968
51%Electricity
49%Fossil Gas
0%Other
15,319,914 14,693,554 457.3 178,172 1.0
2022 C F B A 23.52,990
48%Electricity
52%Fossil Gas
0%Other
15,733,725 17,293,585 487.8 178,172 1.0
2023 C F B A 23.52,997
49%Electricity
51%Fossil Gas
0%Other
15,368,043 15,958,787 468.8 127,535 1.0

* Note on Rankings: Rankings and medians are among included buildings, which are those who reported under the Chicago Energy Benchmarking Ordinance for the year 2023, which only applies to buildings over 50,000 square feet.

** Note on Bill Estimates: Estimates for gas and electric bills are based on average electric and gas retail prices for Chicago in 2021 and are rounded. We expect large buildings would negotiate lower rates with utilities, but these estimates serve as an upper bound of cost and help understand the volume of energy a building is used by comparing it to your own energy bills! See our Chicago Gas & Electric Costs Source (opens in a new tab) for the original statistics.