Hawthorne House 

3450 N Lake Shore Drive, Chicago IL, 60657 Find on Google Maps (opens in a new tab)

Chicago Building ID: 159637

Building Info

Square Footage
530,632 sqft
Higher than 90% of all buildings
4.3x median
124,364 sqft
4.1x median Multifamily Housing
129,789.5 sqft
Built
1968
Primary Property Type
Multifamily Housing
Community Area
Lake View
Ward
44
Owner
Not Tagged

Emissions & Energy Information for 2023

Greenhouse Gas Intensity C
5.9 kg CO2e / sqft
Lower than 56% of all buildings
1.0x median
6.2 kg CO2e / sqft
1.1x median Multifamily Housing
5.6 kg CO2e / sqft
201520235104.89.6
Total Greenhouse Gas Emissions
3,119 tons CO2e
Higher than 88% of all buildings
3.7x median
841.4 tons CO2e
4.3x median Multifamily Housing
732.7 tons CO2e
201520232,5655,0692,5655,069

Years Reported 9/9
A Help icon

  • 2015 data reported

    2015

  • 2016 data reported

    2016

  • 2017 data reported

    2017

  • 2018 data reported

    2018

  • 2019 data reported

    2019

  • 2020 data reported

    2020

  • 2021 data reported

    2021

  • 2022 data reported

    2022

  • 2023 data reported

    2023

Energy Breakdown for Hawthorne House

Fossil Gas Use (aka Natural Gas)
33,638,053 kBtu
Est. Gas Bill: $401,000 for 2023**
Higher than 96% of all buildings
6x median
5,517,828 kBtu
6x median Multifamily Housing
6,105,563.2 kBtu
2015202330,881,52040,864,05530,881,52040,864,055
Electricity Use
9,521,993 kBtu
Est. Electric Bill: $399,000 for 2023**
Higher than 78% of all buildings
2.7x median
3,580,332.6 kBtu
3.5x median Multifamily Housing
2,710,821.8 kBtu
201520235,293,77916,596,6305,293,77916,596,630

Energy Mix D

Total Energy Use: 43,160,048 kBTU

22%Electricity78%Fossil Gas
Help icon
View Extra Technical & Historic Info
Source Energy Usage Intensity
Not Reported

This data was not reported for this building this year, which likely means a value of zero for this field.

201520239316392.7162.8
Site Energy Usage Intensity
Not Reported

This data was not reported for this building this year, which likely means a value of zero for this field.

Full Historical Data Table for Hawthorne House

Year Overall
Grade
Emissions
Intensity
Sub-Grade
Energy Mix
Sub-Grade
Reporting Mix
Sub-Grade
GHG Intensity kg CO2e / sqft GHG Emissions metric tons CO2eEnergy Mix Electricity Use kBTU Fossil Gas Use kBTUSource EUI kBTU / sqft Floor Area sqft Chicago Energy
Rating
Energy Star
Score
2015 C C D A 9.65,069
34%Electricity
66%Fossil Gas
0%Other
16,596,630 32,654,746 162.8 530,632 - 19.0
2016 C C D A 8.84,671
31%Electricity
69%Fossil Gas
0%Other
15,498,021 34,176,067 159.3 530,632 - 24.0
2017 C A F A 5.12,731
16%Electricity
84%Fossil Gas
0%Other
5,902,678 30,881,520 96 530,632 - 89.0
2018 C B D A 6.93,648
22%Electricity
78%Fossil Gas
0%Other
10,257,421 36,561,697 126.5 530,632 3.5 57.0
2019 B B D A 5.83,097
12%Electricity
88%Fossil Gas
0%Other
5,572,458 40,864,055 110.3 530,632 3.5 73.0
2020 B A D A 4.82,565
14%Electricity
86%Fossil Gas
0%Other
5,293,779 32,753,365 92.7 599,388 4.0 88.0
2021 C B C A 5.83,061
23%Electricity
77%Fossil Gas
0%Other
9,506,224 32,082,262 113.6 599,388 3.0 66.0
2022 C B C A 5.62,989
22%Electricity
78%Fossil Gas
0%Other
9,210,670 33,436,515 114.8 599,388 3.0 70.0
2023 C C D A 5.93,119
22%Electricity
78%Fossil Gas
0%Other
9,521,994 33,638,054 116.8 530,632 2.5 52.0

* Note on Rankings: Rankings and medians are among included buildings, which are those who reported under the Chicago Energy Benchmarking Ordinance for the year 2023, which only applies to buildings over 50,000 square feet.

** Note on Bill Estimates: Estimates for gas and electric bills are based on average electric and gas retail prices for Chicago in 2021 and are rounded. We expect large buildings would negotiate lower rates with utilities, but these estimates serve as an upper bound of cost and help understand the volume of energy a building is used by comparing it to your own energy bills! See our Chicago Gas & Electric Costs Source (opens in a new tab) for the original statistics.

Data Source: Chicago Energy Benchmarking Data (opens in a new tab)

What Should We Do About This?

Own this Building? Take Action.